FREE DELIVERY TODAY - 10% Discount for next 3 orders! Place your 1st order in.
CTM CX-10HN – 10,000 BTU Condenser – Marine Split A/C Unit – 230V – 50/60HZ – R410A – NMEA 2000
CTM CX-10HN Split Condenser – 10,000 BTU (NMEA 2000) features a premier 230V thermal architecture designed for international smart-yacht applications. Delivering 10,000 BTUs, this model utilizes an integrated CAN-bus interface to communicate with the vessel’s primary display system, ensuring precision thermal management and high-efficiency operation for guest quarters in tropical high-humidity saltwater environments.
- Thermal Output: 10,000 BTU/hr with NMEA 2000 digital control.
- System Architecture: 230V International-spec digital condenser.
- Power Requirements: 230V AC / 50-60Hz Single Phase.
- Vessel Integration: Optimized for networked international guest staterooms.
- Warranty Coverage: CTM Marine 2-year limited factory protection.
Products are almost sold out
available only:
3In Stock
Description
CTM CX-10HN 10,000 BTU – Marine Split Condenser
The CTM CX-10HN 10,000 BTU condenser system delivers robust climate management for mid-sized cabins in USA coastal waters through a Marine Split A/C Unit. Engineered with smart NMEA 2000 connectivity, this hardware provides the crew with instant feedback regarding system pressures and electrical consumption via the onboard backbone. The high-grade titanium condenser coil provides superior longevity and resistance against the chemical aggression found in coastal seawater cooling loops.
The CTM CX-10HN 10,000 BTU Marine HVAC Technology operates on a 230V dual-frequency platform to ensure seamless functionality across both North American and European power grids. This model utilizes an environmentally friendly R410A refrigerant cycle to achieve high seasonal energy efficiency while reducing the vessel’s overall carbon footprint. Every unit undergoes rigorous factory pressure testing to ensure that the split-system connections maintain vacuum integrity during heavy offshore transits.
Key Technical Specifications
- Ten thousand BTU capacity.
- Smart NMEA 2000 communication.
- Dual frequency 50/60 Hertz.
- Titanium seawater condenser coil.
- Universal 230 volt connection.
- High performance rotary compressor.
- Safe R410A refrigerant gas.
- Compact engine room footprint.
CTM CX-10HN 10,000 BTU Split Condenser (230V) Full Specs
| Model Series | CX-Series Split Condenser (Heat & Cool) |
| Cooling Capacity | 10,000 BTU/h |
| Heating Capacity | Yes (Reverse Cycle) |
| Voltage / Frequency | 230V | 50/60Hz |
| Connectivity | NMEA 2000 Ready |
| Running Current (Avg) | 3.1A (@230V) |
| Startup Current (LRA) | 16A |
| Condenser Type | Titanium |
| Weight | 22.7 kg (50 lbs) |
| Dimensions (LxWxH) | 13.5" x 11.5" x 12" |
CTM CX-10HN 10,000 BTU Split System Condenser (230V) Guide
What are the features of the CTM CX-10HN Split Unit?
The CTM CX-10HN is a 10,000 BTU reverse-cycle split-system condenser (230V) designed for small-to-mid sized cabins on international yachts. It provides both cooling and heating while keeping the compressor noise isolated. Standard features include a titanium condenser coil for extreme durability and NMEA 2000 connectivity, offering a smart and quiet climate control solution for global cruising.
What are the electrical requirements for CX-10HN 230V?
Operating on 230V (50/60Hz), this unit is very energy-efficient, drawing only about 4.5 Amps. It requires a dedicated 10A marine circuit breaker. Its universal frequency compatibility makes it a perfect global product, while the NMEA 2000 interface allows for seamless control via the vessel’s network, reducing the need for multiple independent control panels in every stateroom.
How to maintain the CX-10HN sea water circuit?
The 10,000 BTU unit requires a sea water flow of at least 200-250 GPH. Maintenance involves checking the sea strainer weekly and an annual descaling flush of the titanium heat exchanger. Titanium’s resistance to erosion ensures the unit maintains its thermal performance far longer than standard models, providing reliable comfort in both cooling and heating modes.
How is the CX-10HN installed in a split system?
The CX-10HN condenser is installed in a machinery space and connected to a remote cabin evaporator via refrigerant lines. This configuration significantly reduces noise in the sleeping quarters. The NMEA 2000 integration further modernizes the installation by allowing temperature and system status monitoring from any compatible display on the yacht’s network.
What is the build quality of the CX-10HN?
Built on a rugged 304 stainless steel base, the CX-10HN is designed for longevity in the marine bilge environment. It weighs approximately 50 lbs and is engineered for quiet, reliable service. Backed by a 2-year warranty and featuring a corrosion-proof titanium condenser, the CX-10HN is a high-value investment for boaters who prioritize a premium, integrated cabin environment.
You must be logged in to post a review.
Log in
By continuing, you accept the Terms and Conditions, Shipping Policy, and Our Privacy Policy
You dont have an account yet? Register Now