CTM EV-8 – 8,000 BTU Evaporator – Marine Split A/C Unit – 115V – 50/60HZ
CTM EV-8 – 8,000 BTU Evaporator – Marine Split A/C Unit – 115V – 50/60HZ accelerates localized v-berth thermal regulation through an 8,000 BTU/h capacity profile on 115V networks, integrating ruggedized compact chassis layouts for long-term marine saltwater corrosion protection.
- Optimizes mid size berths small saloons
- Draws an efficient 0.8A running current
- Features multi directional 360 rotatable blowers
- Requires compact 4 inch duct paths
- Minimizes total asset weight to 13lbs
Products are almost sold out
available only:
2In Stock
Description
CTM Marine EV-8 Split System Evaporator Marine Air Handler
The CTM Marine EV-8 deploys a space-saving split-system framework engineered to supply a powerful 8,000 BTU/h climate control solution directly to localized medium staterooms up to 300 cu.ft. The heavy-duty 11.5×10.5×10.5-inch structural chassis installs remotely within narrow bulkhead spaces, pumping conditioned air smoothly at 240 CFM through a 4-inch duct connection to prevent hot spots. This modern configuration delivers exceptional thermal regulation on complex luxury vessels, providing the ultimate choice over a traditional 230v chilled water fan coil alternative layout.
Operational safety on a single-phase 115V 50/60Hz electrical infrastructure is secured by an integrated low-draw fan motor pulling an ultra-efficient 0.45A running amperage. The 13 lbs indoor assembly utilizes a rugged ABS composite pan paired with premium aluminum/copper fin coils, holding localized cabin vibration sound emissions to a whisper-quiet minimum. External condensation plumbing lines link directly to a 1/2-inch drain port, finishing an IP22-protected build fully satisfying CE and ISO 8846 requirements.
Technical Capabilities and Attributes for CTM Marine EV-8:
- Efficient 115V single phase split system evaporator unit
- High performance 8,000 BTU cooling and reverse heating
- Advanced aluminum copper fin coil maximizes indoor heat exchange
- Rigid ABS composite collection pan prevents structural rust damage
- Extremely low 0.45A running amperage minimizes auxiliary load
- Internal ventilation blower ensures quiet under berth cabin operation
- Standard 4-inch duct discharge connection collar fitting ring
- Ignition protected design fully complies with ISO 8846 parameters
- Lightweight 13 lbs chassis optimizes restricted locker spaces
- Pre charged eco conscious R-410A structural refrigerant loop
Alloy Thermodynamics and Heat Dissipation
Aluminum/copper fin coils provide maximum thermal transfer by absorbing localized cabin heat across a high-density fin pattern. The system uses a specialized fan wheel array to drop cabin moisture levels rapidly, guaranteeing stable technical operations as part of an integrated NMEA 2000 marine HVAC infrastructure. This advanced thermodynamic matrix provides constant performance, maintaining optimal air temperatures over years of marine service.
Comprehensive Manufacturer Coverage and Service Protocols
A comprehensive 2-year factory warranty protects all structural parts against defects under standard marine operating protocols. This coverage delivers direct component remediation through authorized dealers, ensuring original engineering tolerances are maintained without out-of-pocket costs. Vessel owners enjoy peace of mind knowing mechanical and electronic infrastructure elements are fully secured.
Dimensional Layout and Hull Configuration Sizing
Vessels measuring 22-30ft are perfectly sized for this remote-mounted marine climate system. It is uniquely engineered to serve interior cabin spaces up to 300 cu.ft that require a companion 8,000 BTU condensing unit layout. Seamless hardware optimization balances continuous moisture extraction, letting operators maximize layout space while reducing internal equipment strain.
CTM EV-8 Specs
| Brand | CTM Marine |
| Exact Model Code / SKU | EV-8 |
| Country of Origin | USA |
| System Architecture | Split System Evaporator (Air Handler) |
| Cooling Capacity - BTU/h | 8,000 BTU/h |
| Cooling Capacity - kW/Watts | 2.34 kW |
| Heating Capacity - BTU/h | 8,000 BTU/h (When paired with reverse-cycle condenser) |
| Reverse Cycle Heating Function | Yes (Dependent on Condenser) |
| Electrical Voltage | 115V |
| Alternating Current Frequency | 50/60 Hz |
| Electrical Phase | Single Phase |
| Full Load Amps - FLA Cooling | 0.45 A |
| Full Load Amps - FLA Heating | 0.45 A |
| Max Circuit Breaker Size | 5 A (Or bundled with Condenser protection) |
| Refrigerant Type | R-410A |
| Evaporator Airflow Capacity | 240 CFM |
| Duct Discharge Connection Diameter | 4 inches (102 mm) |
| Condensate Drain Connection Size | 1/2 inch (12.7 mm) |
| Physical Dimensions - Unit | 11.5 x 10.5 x 10.5 inches (292 x 267 x 267 mm) |
| Net Weight | 13 lbs (5.9 kg) |
| Chassis & Condenser Material | ABS Composite Pan & Aluminum/Copper Fin Coil |
| Standard Factory Warranty | 2 Years |
| Application & Sizing Guidance | Medium stateroom air handler optimized to distribute low-noise airflow for cabins up to 300 cu.ft when paired with an 8,000 BTU condenser. |
What's in the Box
- 1x EV-8 8000 BTU 115V Cabin Evaporator Unit
- 1x Digital Thermostat Display Touchscreen Panel
- 1x Multi-Pin Thermostat Display Connecting Cable
- 1x Integrated High-Velocity Multi-Speed Blower Fan
- 1x Composite Lightweight Condensate Collection Tray
- 1x User Manual
CTM EV-8 Air Handler FAQ
How is airflow distributed on the CTM EV-8?
A high-velocity rotatable blower assembly coordinates the three-hundred-sixty-degree air distribution output through the CTM EV-8 air handler. This premium air delivery design enables installers to rotate the blower casing to any angle, routing high-velocity airflow seamlessly into tight cabin spaces. It ensures rapid thermal regulation and whisper-quiet operation across mid-size berths and small saloons.
How much current does this model draw?
The CTM EV-8 draws an average running current of 0.8A when linked to a domestic 115V 50/60Hz power network node. This incredibly low current draw enables boat operators to run the fan system continuously without impacting the vessel's primary electrical grid balances. Vessel technicians should note this minor electrical load when sizing secondary multi-station breaker panels.
Which factory performance bounds rule this compact unit?
An 8,000 BTU/h cooling capacity paired with a 4-inch output duct framework anchors the mechanical tolerances for this machine:
| Mechanical Core | Certified Engineering Blueprint Specs |
|---|---|
| Thermal Capacity | 8,000 BTU/h air handling output cross-compatible with automated split system remote condensors for cooling options |
| Electrical Input | 115V single-phase hardware network cross-compatible with domestic harbor grids and offshore generator sets natively |
| Refrigerant Lines | Dedicated line set matching featuring a 3/8-inch suction line paired natively with a 1/4-inch liquid tube path |
| Chassis Framework | Compact split air handler design measuring 11.5 x 8.5 x 10.5 inches weighting 13 lbs tailored for mid-size berths |
Additional information
| Brand | CTM Marine |
|---|---|
| Cooling Capacity | 8000 BTU |
| Frequency | 50/60 Hz Dual |
| System Type | Split System Evaporator |
| Voltage | 115V |
You must be logged in to post a review.