CTM CT-10HN – 10,000 BTU Marine Air Conditioner 230V 50/60HZ NMEA 2000
CTM CT-10HN Marine AC – 10,000 BTU (NMEA 2000) features a refined high-density power design for 230V global grids, incorporating a full CAN-bus interface. Delivering 10,000 BTUs, this model utilizes an anti-corrosive titanium-condenser variant option and a rotatable high-velocity blower, providing the real-time data feedback and thermal stability required for digitally networked guest staterooms.
- Thermal Output: 10,000 BTU/hr with NMEA 2000 monitoring.
- Compressor Type: Industrial-grade 230V rotary unit.
- Power Requirements: 230V AC / 50-60Hz Single Phase.
- Vessel Integration: Optimized for networked guest suites and mid-sized cabins.
- Warranty Coverage: CTM Marine 2-year limited factory protection.
Products are almost sold out
available only:
6In Stock
Description
CTM CT-10HN NMEA 2000 Ready Chilled Water Marine Air Handler Alternative
Direct glass-bridge integration defines the CTM Marine CT-10HN, a network-ready 10,000 BTU/h self-contained climate system operated via multi-function displays over standard NMEA 2000 marine HVAC data networks. This intelligent 24.5kg direct expansion unit manages localized thermal profiles across 25 to 35-foot cruisers by driving a steady 350 CFM forced airflow through its 5-inch duct connection. The compact 480x300x320mm chassis layout slides neatly behind tight stateroom bulkheads, maximizing physical layout utility while avoiding structural restrictions.
Running safely off restricted onboard energy reserves, the single-phase 230V 50/60Hz machinery framework maintains extreme efficiency by drawing a lean 4.2A operational current and 950W max load. The advanced mechanical core relies on a high-pressure rotary compressor split-connected to a cupro-nickel sea water loop heat exchanger for optimal anti-fouling security. Functioning smoothly within a wide 10-40°C environmental window, this IP22-rated, CE-approved vessel climate device dampens structural resonance to cap sound pressure limits at 52 dB(A).
Key Features of CTM Marine CT-10HN:
- Advanced NMEA 2000 marine HVAC bus data channel screen integration
- Targeted 10,000 BTU/h high capacity reverse cycle climate loop
- Constant 350 CFM high velocity forced cabin air ventilation
- High voltage single phase 230V motor system electrical framework
- Lean 4.2A active operational running current power draw
- Anti corrosive cupro nickel sea water loop heat exchanger
- Factory integrated high pressure rotary compressor assembly machinery block
- Space saving 24.5kg net chassis housing physical footprint
- Isolates internal acoustic rumble below 52 dB(A) parameters
- Full CE marine safety network certification ready structural design
Digital Network Climate Tracking
Smart NMEA 2000 automated bus data channels integrate this premium handler directly into your onboard environment. It communicates natively with modern marine electronics, allowing crew members to tweak zone temperatures using multi-function helm controllers. This advanced connectivity eliminates old analog control layout challenges, streamlining systemic diagnostic checks during standard maintenance windows.
Comprehensive System Protection Plan
Solid technical factory warranty backing protects this advanced network-ready air handler for a full two year window. This factory warranty guarantees that both the heavy-duty hydronic mechanical core and the NMEA 2000 data transceivers operate smoothly without failure. It minimizes financial risk for yacht owners executing complete marine HVAC system modernization overhauls.
Hull Matching Guidelines
Cruisers tracking 25 to 35 feet deliver an exact application use fitment for this 10,000 BTU/h network air handler. The 350 CFM constant air volume is dynamically balanced to satisfy the ventilation demands of large main cabin areas or combined pilot houses. It ensures consistent temperature management while fitting neatly into standard sub-cabinet yacht spaces.
CTM CT-10HN Specs
| Brand | CTM Marine |
| Model | CT-10HN |
| Series | NMEA 2000 Ready |
| Country of Origin | USA |
| System Architecture | Self-Contained |
| Cooling Capacity | 10,000 BTU/h |
| Heating Capacity | 10,000 BTU/h |
| Voltage | 230V |
| Frequency | 50/60Hz |
| Phase | 1Ph |
| Running Amperage | 4.2A |
| Startup/LRA | 16A |
| Power Consumption | 950W |
| Refrigerant Type | R-410A |
| Compressor Type | Rotary |
| Condenser Coil Material | Cupro-Nickel |
| Evaporator Coil Material | Aluminum |
| Air Flow Rate | 350 CFM |
| Static Pressure | TBC - Contact Manufacturer |
| Dimensions - Unit | 480x300x320mm |
| Dimensions - Elec Box | 200x150x80mm |
| Net Weight | 24.5kg |
| Noise Level | 52 dB(A) |
| Water Pump Req | 5.0 GPM |
| Min/Max Seawater Flow | 4.0-6.0 GPM |
| Seawater Inlet/Outlet | 5/8" MPT |
| Duct Connection | 5" |
| Control Interface | NMEA 2000 / Digital |
| Operating Temp Range | 10-40°C |
| IP Rating | IP22 |
| Certifications | CE, NMEA 2000 |
| Standard Warranty | 2 Years |
| Service Interval | 6 Months |
| Typical Installation | Salon/Stateroom |
| Recommended Vessel Length | 25-35ft |
What's in the Box
- 1x CTM CT-10HN 10,000 BTU Self-Contained Marine Air Conditioner (230V - 50/60Hz)
- 1x Integrated NMEA 2000 Embedded Control Board
- 1x High-Velocity 360-Degree Rotatable Turbo Blower
- 1x Corrosion-Proof Titanium Seawater Circulating Coil
- 1x Heavy-Duty Stainless Steel Base Pan with ABS Drain Tray
- 1x Removable and Washable Mesh Air Filter
- 1x Remote Air Temperature Sensor Probe
- 1x User Manual and Installation Guide
CTM CT-10HN Marine AC FAQ
What voltage rating does CT-10HN use?
CTM CT-10HN utilizes a standard 230V power input. This single-phase electrical layout is designed for international power grids and heavy-duty European or US marine generator systems, allowing yacht owners to implement premium climate management without loading the lower-voltage ship service lines unevenly.
What are the physical dimensions of CT-10HN?
CTM CT-10HN has a footprint of 20x12x13.25 inches. These tight dimensional limits facilitate easy drop-in mounting behind salon bulkheads or inside cockpit storage lockers, presenting an efficient installation alternative for vessel retrofits when older, bulkier mechanical systems are being updated or replaced entirely.
When is CTM CT-10HN best applied?
CTM CT-10HN is best applied in dedicated crew quarters and guest cabins on larger yachts. The 230 Volt circuit structure satisfies commercial boat requirements, utilizing integrated NMEA 2000 telemetry to connect directly with helm multi-function displays for centralized temperature monitoring across the vessel network.
| Chassis Detail | Official Metric |
|---|---|
| Output Rating | 10,000 BTU |
| Plumbing Inlet | 5/8 inch |
| Plumbing Outlet | 5/8 inch |
| Duct Ring | 5 inches |
Additional information
| Brand | CTM Marine |
|---|---|
| Cooling Capacity | 10000 BTU |
| Frequency | 50/60 Hz Dual |
| System Type | Self-Contained |
| Voltage | 230V |