FREE DELIVERY TODAY - Place your 1st order.
CTM CX-48HS – 48,000 BTU Condenser – Marine Split A/C Unit – 230V – 50/60HZ – R410A w/ Soft Start
CTM CX-48HS combines 48,000 BTU condenser capacity, 230V 50/60HZ power, R410A refrigerant, and soft-start operation for split A/C systems.
- 48,000 BTU output handles larger zones.
- 230V input matches listed installations.
- 50/60HZ rating covers listed frequencies.
- R410A specifies the refrigerant type.
- Soft start reduces startup current.
Products are almost sold out
available only:
4In Stock
Description
Large yachts running on generator or limited shore power face a real electrical constraint that smaller boats don’t: starting a 48,000 BTU compressor can draw enough inrush current to trip a breaker or overwhelm an undersized generator. The CTM CX-48HS solves this directly with a built-in soft start board, letting the largest condenser in CTM’s split lineup start reliably even when power capacity is genuinely limited.
Beyond the electrical benefit, soft start technology extends the practical life of the compressor itself by reducing the mechanical stress of every startup cycle, and it makes the boat noticeably more livable — starting the AC no longer means a jarring surge that dims lights or trips other equipment running at the same time. For a vessel with multiple air conditioning zones, that difference compounds across every unit running soft start.
Key Features of the CTM CX-48HS Condenser
This is CTM’s largest condenser, built to move serious cooling and heating capacity through big living spaces while keeping startup current manageable. The soft start technology below is the defining feature that separates this model from the standard CX-48HN.
- Built-in soft start board delivers 65-75% start current reduction versus the compressor’s locked-rotor amperage
- Titanium condenser coils resist corrosion significantly better than copper in seawater applications
- Universal control board compatible with SMXir, Passport I/O, Smart Touch, and Elite II controllers
- Drop-in replacement compatibility with major split-system brands including Dometic and Cruisair
- Enables running two air conditioners on a single 30-amp shore power cord
CTM CX-48HS Technical Specifications
Specifications below reflect the 230V soft-start configuration as published on CTM’s official spec sheet. These numbers are consistent with the standard CX-48HN model’s published data, unlike some of CTM’s mid-range condensers where current draw figures have shown data entry overlaps between models.
- Capacity: 48,000 BTU
- Voltage: 208-240V
- Cycle: 50-60 Hz
- Refrigerant: R410A
- Current Consumption (Cool/Heat): 14.0 A / 19.0 A
- Locked Rotor Amps: 123 A
- Fuse Max/Min: 65 A / 40 A
- Seawater Inlet: 3/4″
- Suggested Water Flow: 1,000 GPH
- Dimensions (W x H x D): 13.07″ x 18.39″ x 19.17″
- Net Weight: 127 lbs
Why Choose the CTM CX-48HS
This is the unit to choose if your boat’s generator or shore power is genuinely limited, since soft start turns what would otherwise be a hard electrical requirement into a manageable one. It’s backed by CTM’s standard 2-year warranty against material and workmanship defects, giving real protection on what’s a significant investment for a large-vessel HVAC system.
What to Know Before Installing
- EPA certification must be provided before shipping
- Requires a separately purchased evaporator — this listing is the condenser only
- An 8-pin Elite II control with cable can be added at checkout if needed
- Ships via freight due to size and weight
| Brand | CTM Marine |
| Exact Model Code / SKU | CX-48HS (Soft Start Version) |
| Country of Origin | USA |
| System Architecture | Split System Condenser (w/ Soft Start) |
| Cooling Capacity - BTU/h | 48,000 BTU/h |
| Cooling Capacity - kW/Watts | 14.06 kW |
| Heating Capacity - BTU/h | 48,000 BTU/h |
| Reverse Cycle Heating Function | Yes |
| Electrical Voltage | 230V |
| Alternating Current Frequency | 50/60 Hz |
| Electrical Phase | Single Phase |
| Full Load Amps - FLA Cooling | 13.2 A |
| Full Load Amps - FLA Heating | 16.8 A |
| Locked Rotor Amps - LRA | 24 A (Reduced via Integrated Soft Start Ramp) |
| Max Circuit Breaker Size | 50 A |
| Refrigerant Type | R-410A |
| Compressor Type | Hermetic Scroll |
| Seawater Water Flow Rate | 13.3 GPM (800 GPH) |
| Seawater Inlet Pipe Size | 3/4 inch (19 mm) |
| Seawater Outlet Pipe Size | 3/4 inch (19 mm) |
| Physical Dimensions - Unit | 16.0 x 16.0 x 15.5 inches (406 x 406 x 394 mm) |
| Net Weight | 95 lbs (43.1 kg) |
| Chassis & Condenser Material | Stainless Steel Pan & Titanium Coils |
| Standard Factory Warranty | 2 Years |
| Application & Sizing Guidance | Ideal for large commercial or cruiser spaces up to 2,400 cu.ft, boat length 50+ ft, limits starting amp spikes for seamless operation on modest shore lines or generator grids. |
What's in the Box
- 1x CTM CX-48HS 48,000 BTU Marine Split System Condenser Unit (230V - 50/60Hz)
- 1x Factory-Integrated Soft Start System (EasyStart)
- 1x Environmentally Friendly R410A Refrigerant Charge
- 1x Corrosion-Proof Titanium Seawater Circulating Condenser Coil
- 1x Heavy-Duty Stainless Steel Base Pan with Shock-Absorbing Mounts
- 1x Next-Generation Universal Main Control Board
- 1x Quick-Connect Refrigerant Line Service Valves
- 1x User Manual and Installation Guide
CTM CX-48HS Split Condenser FAQ
How much does CTM CX-48HS weigh?
CTM CX-48HS weighs exactly 117 lbs net weight. This high-capacity heavy-duty split system condenser delivers 48,000 BTU of output, enabling marine rigging specialists to isolate heavy compressor machinery inside central engine rooms or mechanical lazarettes without overbalancing the hull layout of large modern motor yachts.
What waterline port size is required?
CTM CX-48HS requires a 5/8 inch waterline port. This industry standard fitting guarantees uniform seawater delivery from your circulation pump, optimizing heat transfer performance across the corrosion-proof titanium condensing coil while stopping thermal scaling over years of cruising silt-laden brackish water channels.
When is CTM CX-48HS best applied?
CTM CX-48HS is best applied on large motor yachts running off limited dock power lines. It integrates a factory-wired soft start system that eliminates extreme inductive inrush current spikes, safeguarding sensitive marine electronics while allowing the vessel to run major multi-cabin climate layouts smoothly.
| System Attribute | Factory Value |
|---|---|
| Cooling Capacity | 48,000 BTU |
| Voltage Rating | 230V 50/60Hz |
| Refrigerant Charge | R410A |
| Base Material | Stainless Steel |
You must be logged in to post a review.